Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO2COMP application module.
Group
Bus
Syntax
BUS:B<x>:RS232C:DISplaymo de {FRAme|PACKET}
BUS:B<x>:RS232C:DISplaymo de?
Arguments
FRAme displays each frame as a single entity.
PACKET displays a group of frames terminated with a single frame denedbythe
BUS:B<x>:RS232C:DELImiter command or the front panel.
BUS:B<x>:RS232C:PARity
Sets or returns the RS232C parity for bus <x>, where x is the bus number.
Conditions
This command requires a DPO2COMP application module.
Group
Bus
Syntax
BUS:B<x>:RS232C:PARity {NONe|EVEN|ODD}
BUS:B<x>:RS232C:PARity?
Arguments
NONe species no parity.
EVEN species even parity.
ODD species odd parity.
NOTE. 9 data bits (BUS:B<x>:DATABITS 9) does not support parity. Changing
the parity with the PI while using 9 data bits, has no effect.
BUS:B<x>:RS232C:POLarity
Sets or returns the RS232C polarity for bus <x>, where x is the bus number.
Conditions
This command requires a DPO2COMP application module.
Group
Bus