Host High Speed Electrical Test Procedure Revision 1.4
9. Click Enumerate Bus using the High Speed Electrical Test Tool and capture the CHIRP
handshake as in the following figure.
Note: Instead of enumerating the device, an alternative method to generate the chirp signal, is
to disconnect and reconnect the unit under test (device) to the port.
Figure 16: High Speed Chirp
Host Chirp Response
10. The application measures the host’s Chirp response timing (TWTRSTFS) EL_33.. This is the
time between the device’s de-assertion of Chirp-K and the start of alternate Chirp-K and Chirp-
J sent by the host. The timing should be ≤ 100 μs.
11. The application measures (EL_34) and record the durations of the individual Chirp-K and
Chirp-J states and verifies that both are between 40 μs ≤ TDCHBIT ≤ 60 μs (EL_31).
12. Click Chirp on the application and select Host option EL_35. Click Run.
13. Unplug the known good device and then reattach it.
14. Ensure the oscilloscope trigger is armed.
28